GBC FusionPunch II Service Manual page 280

With stacker and bypass
Hide thumbs Also See for FusionPunch II:
Table of Contents

Advertisement

GP-1 Stacker 2 Output Test
1. Press the DIAGNOSTICS key until the LCD displays the Stacker
Output screen as shown in the table below.
NOTE: OUTXX corresponds to the LED on the Stacker I/O
PWB. Use the Left or Right Arrows to move the cursor to the
desired output as shown in Table 6-8. The outputs can be turned
on individually by pressing the UP Arrow when the cursor is
under the selected output. In the same manner, the outputs can
be turned off individually by pressing the DOWN Arrow when the
cursor is under a selected output.
Table 6-8 Stacker 2 Outputs
S2
OUTC1 SheetExit
01
0000000000000000
S2
OUTC2 EndSetExit
02
0000000000000000
S2
OUTC3 Cycle Up
03
0000000000000000
S2
OUTC4 Finisher 1
04
0000000000000000
S2
OUTC5 Finisher 2
04
0000000000000000
S2
OUTC6 StackerDeck
06
0000000000000000
S2
OUTC7 Stacker Dir
07
0000000000000000
S2
OUTC8 Stack Oring
08
0000000000000000
S2
09
0000000000000000
S2
OUTB2 StackByPass
010
0000000000000000
S2
011
0000000000000000
S2
012
0000000000000000
GP-1 Stacker 2 Output Test
Not Used
Not Used
Not Used
S2
OUTB5 StackerGate
013 0000000000000000
S2
OUTB6 Offset 2
014 0000000000000000
S2
OUTB7 Offset 1
015 0000000000000000
S2
OUTB8 Stacker Tap
016 0000000000000000
Output LEDs (may vary in brightness)
Figure 6-3 Stacker I/O PWB
NOTE: The values shown in Table 6-8 may not correspond
with the values displayed on the LCD.
12/2003
6-8
GBC FusionPunch II Service Manual

Advertisement

Table of Contents
loading