GBC FusionPunch II Service Manual page 284

With stacker and bypass
Hide thumbs Also See for FusionPunch II:
Table of Contents

Advertisement

GP-2 Enter / Exit Test Mode
Procedure
In the test mode, the technician checks the
machine operation to isolate the cause of a
malfunction.
1. Perform General Procedures 1 (GP 1) to
enter Diagnostics.
2. To enter the test mode, press ONLINE /
OFFLINE button once. The LCD will display
two lines of text. The top line will flash the
following messages, instructing which
arrows to use to change the different
configuration possiblities.
The bottom line of text will display the
current configuration setup in the system.
< Change Run Mode
^ Change Punch Mode
> Change Destination
3. Press the left arrow "<" until the bottom line
of the LCD displays "Test/".
4. Press Stop/Reset to save this configuration.
WARNING
By pressing the START
button, the Test mode will start and all
Motors and Solenoids will turn ON.
Make sure that there are no loose
items lying in the paper path and keep
hands and clothing out of the
machine.
5. To begin testing the machine, open all Top
Covers, cheat/override the Interlocks and
press START. While in test mode, the
machine performs all normal operations.
6. Use the 3 charts to the right to verify proper
operation of each component in each
module.
GP-2 Enter / Exit Test Mode Procedure
7. To exit the Test mode, press the STOP/RESET button and then turn Punch Main Power
Switch / Circuit Breaker OFF and then back ON.
Punch Component
Transport Motor
Punch Motor
Back Gauge Solenoid
Punch Clutch
Punch Sheet Eject
Solenoid
Stacker Component
Stacker Tappers
Offset Solenoids
Stacker Tray Motor
Bypass Component
Bypass Motor
Bypass Gate Solenoid
12/2003
6-12
Normal Operation
The Document Transport Timing Belt
moves smoothly without excessive
noise.
The Die Pins move up and down.
The Back Gauge Solenoid actuates
three times each second.
The Punch Clutch actuates three times
each second.
The Punch Sheet Eject Solenoid
actuates three times each second.
Normal Operation
The Stacker Tappers actuate three times
each second.
The Offset Solenoids actuate alternately
each second.
If the Stacker Tray is in the maximum
vertical position, the Tray Motor lowers
the Tray one position a second.
Normal Operation
The Bypass Motor Timing Belt moves
smoothly without excessive noise.
Activates when test mode is started and
deactivates when the Bypass Motor
comes on.
GBC FusionPunch II Service Manual