FusionPunch II Message
Jam Entrance Sensor
A sheet of paper blocks the Entrance Sensor.
The Entrance Sensor is dirty or is not
working correctly.
JamDocXportSensor1
A sheet of paper blocks the Jam Document
Transport Sensor1.
The Jam Document Transport Sensor1 is
dirty or is not working correctly.
JamDocXportSensor2
A sheet of paper blocks the Jam Document
Transport Sensor2.
The Jam Document Transport Sensor2 is
dirty or is not working correctly.
Jam At Punch Sensor
A sheet of paper blocks the Jam at Punch
Sensor.
The Jam at Punch Sensor is dirty or is not
working correctly.
Jam PunchExit Sensor
A sheet of paper blocks the Punch Exit
Sensor.
The Jam Punch Exit Sensor is dirty or is not
working correctly.
System Checks
Table 1-3 FusionPunch II Control Panel Messages
Meaning
Remove the sheet of paper that blocks the Entrance
Sensor.
Use a dry cloth, a Q-tip or a can of air to clean the
Entrance Sensor and the Reflector.
Use a dry cloth, a Q-tip or a can of air to clean the
Document Transport Sensor 1 and the Reflector.
Remove the sheet of paper that blocks the Document
Transport Sensor 2.
Use a dry cloth, a Q-tip or a can of air to clean the
Document Transport Sensor 2 and the Reflector.
Remove any paper from the Punch Sensor and press
Reset.
Use a dry cloth, a Q-tip or a can of air to clean the
Punch Sensor and the Reflector.
Remove any paper from the Punch Exit Sensor and
press Reset.
Use a dry cloth, a Q-tip or a can of air to clean the
Punch Exit Sensor and the Reflector.
Switch on the main power to the Stacker.
12/2003
1-10
Operator Action
GBC FusionPunch II Service Manual
Technician Action
Go to RAP 4.1 Document
Transport JAMs.
Go to RAP 4.1 Document
Transport JAMs.
Go to RAP 4.1 Document
Transport JAMs.
Go to RAP 4.1 Document
Transport JAMs.
For jams in the Document
Transport only, go to RAP 4.1
Document Transport JAMs.
For jams in the Stacker that
block the Punch Exit Sensor,
go to RAP 5.3 Stacker Jams.
If the job was to stack in
Stacker 1, but entered the
Stacker 1 Bypass instead and
jammed there, check LOB6
and LOB7 at
P/J22 on the Stacker 1 I/O
PWB. If these LEDs are lit,
go to RAP 3.2 and
troubleshoot a failure of the
Front Door Interlock for
Stacker 1.
If the job was NOT to stack in
Stacker 1 but still originates in
the Bypass and backs up into
the Punch, go to RAP 5.4
Stacker Bypass Jams.