FusionPunch II Message
Please Empty Stacker
The Stacker is full.
The Stacker Tray was left in the down
position.
Stacker Direction??
The Stacker Tray is moving in the incorrect
direction.
Stacker 1 Door Open
The Stacker Door did not actuate the Stacker
Door Interlock Switch.
Note: This dialog may appear
with other interlock related
dialogs. If it occurs with
Stacker 1 Cover Open, Stacker
2 Door Open, and Stacker 2
Cover Open, ensure all covers
and doors are closed and see
the related error information
below in this table.
Stacker 1 Cover Open
The Stacker Cover did not actuate the
Stacker Cover Interlock Switch.
Note: This dialog may appear
with other interlock related
dialogs. If it occurs with
Stacker 1 Door Open, Stacker
2 Door Open, and Stacker 2
Cover Open, ensure all covers
and doors are closed and see
the related error information
below in this table.
System Checks
Table 1-3 FusionPunch II Control Panel Messages (Continued)
Meaning
Lower the Stacker Tray, unload the paper, raise the
Tray, then press Reset.
Press STOP. Press Raise/Lower Stacker #1 to lower
the Stacker. Press Raise/Lower Stacker #1 again to
raise the Stacker. If error persists or returns, call for
service.
Close the Stacker Door.
Close the Stacker Cover
12/2003
1-12
Operator Action
GBC FusionPunch II Service Manual
Technician Action
Go to RAPs 1.2 AC Power to
the Stacker, RAP 5.1 Stacker
Full, Stacker Almost Full and
Stacker Upper Switches, and
RAP 5.2 Stacker Tray
Direction.
Go to RAP 5.1 Stacker Full,
Stacker Almost Full and
Stacker Upper Switches, and
RAP 5.2 Stacker Tray
Direction.
Remove the rear cover of the
Stacker and observe LED
LOB1, LOB3 and LOB4 on
the Stacker I/O PWB. If they
are flashing dimly, go to RAP
1.5 Stacker +24 VDC Power.
If the LEDs are normal
(flashing brightly) go to RAP
3.2 Stacker Interlock
Switches.
Remove the rear cover of the
Stacker and observe LED
LOB1, LOB3 and LOB4 on
the Stacker I/O PWB. If they
are flashing dimly, go to RAP
1.5 Stacker +24 VDC Power.
If the LEDs are normal
(flashing brightly) go to RAP
3.2 Stacker Interlock
Switches.