GBC FusionPunch II Service Manual page 38

With stacker and bypass
Hide thumbs Also See for FusionPunch II:
Table of Contents

Advertisement

7. On the Stacker 2 AC/DC Distribution PWB,
check for +24 VDC between P/J 13-24V
and P/J 13-0V.
The voltage is +23.5 VDC to +25.5 VDC.
Y
N
On the Stacker 1 AC/DC Distribution
PWB, check for +24 VDC between
P/J 13-24V and P/J 13-0V.
The voltage is +23.5 VDC to +25.5
VDC.
Y
N
Replace the Stacker 1 AC/DC
Distribution PWB (PL 3.2)
Replace the harness between P/J 13
on the Stacker 1 AC/DC Distribution
PWB and P/J 13 on the Stacker 2 AC/
DC Distribution PWB (PL 6.2B).
Go to Step 8.
8. On the Stacker 2 AC/DC Distribution PWB,
check for +24 VDC between P/J 12-24V
and P/J 12-0V.
The voltage is +23.5 VDC to +25.5 VDC.
Y
N
Replace the Stacker 2 AC/DC
Distribution PWB (PL 3.2).
On the Stacker 2 I/O PWB, check for +24
VDC between P/J 28-24V and P/J 28-0V.
The voltage is +23.5 VDC to +25.5 VDC.
Y
N
Replace the harness between P/J 28
on the Stacker 2 I/O PWB and P/J 12
on the Stacker 2 AC/DC Distribution
PWB (PL 6.2A).
The Stacker 2 +24 VDC Power Circuit are
OK.
RAP 1.5 Stacker +24VDC Power
12/2003
2-14
GBC FusionPunch II Service Manual

Advertisement

Table of Contents
loading