Error codes can be cleared by following the procedures
located in the Gauge Diagnostic Menu sub-section in this
section.

Gauge Diagnostic Menu

DIGITAL GAUGE
The digital gauge has a diagnostic menu that can be used
to diagnose many of the DTCs displayed. To place the
gauge into the diagnostic mode, use the following proce-
dure.
NOTE: The digital gauge has four buttons: upper
left (A), upper right (B), lower left (C), and lower
right (D).
XX352
1. Turn the ignition switch ON.
2. Depress and hold either both the lower left (C) and
lower right (D) or the upper right (B) and lower right
(D) buttons together for approximately three seconds
until "DIAGNOSTIC" appears on the LCD.
XX351
3. Press the center button (SELECT) (lower right but-
ton (D)) to enter diagnostic mode; cycle the display
by pressing either the left or right button to step to
the desired function.
NOTE: The gauge can be utilized dynamically
(engine
running/vehicle
(engine/vehicle stopped).
96
moving)
or
statically
DIAGNOSTIC MODES
Battery (BATTERY VOLTS)
XX343
Display: System DC voltage.
DTC: P0562, P0563
Usage: Verify system voltage under following condi-
tions:
1. Battery voltage with engine and accessories off
(>12.2 VDC for fully charged).
2. Battery voltage with engine idling (charging = 13.8
VDC or greater).
3. Battery voltage with electrical accessories operating,
engine idling (13.5 VDC or greater).
4. Battery voltage starter cranking (10.5-11.5 VDC).
Coolant (COOLANT TEMP)
XX344
Display: Engine coolant temperature as measured by the
ECT sensor.
DTC: P0116, P0117, P0118, P0217, P0480 P0691, P0692
Usage: Monitor coolant temperature to verify the follow-
ing:
1. ECT sensor signal.
2. High Temperature indicator (on @ 230° F (110° C),
off @ 203° F (95° C).
3. Thermostat starts opening @ approximately 181-189° F
(83-87° C), and should be fully open @ approxi-
mately 212 °F (100° C) indicated by a momentary
drop or pause in the rising temperature reading.
4. Fan ON @ 213° F (100.5° C), OFF @ 203° F (95°
C).