Removal
The procedure below details how to remove the serial measurement unit and battery
pack.
1
2
Product manual - IRB 140
3HAC027400-001 Revision: V
4.6.3 Replacing the serial measurement unit and the battery pack
WARNING
Please observe the following before doing any repair work on the manipulator:
Motors and gears are HOT after running the robot! Touching the motors and
gears may result in burns!
Turn off all electric power, hydraulic, and pneumatic pressure supplies to
the robot!
Take any necessary measures to ensure that the manipulator does not
collapse as parts are removed, for example secure the lower arm with fixtures
if removing motor, axis 2.
DANGER
Follow these instruction to prevent the unit to be damaged from ESD:
The unit is sensitive to electrostatic discharge. It will be destroyed if
subjected to electrostatic voltages.
Before handling, make sure you are grounded through a special ESD wrist
bracelet or similar.
CAUTION
This component is classified as hazardous waste and must be disposed of
accordingly!
If in doubt of the correct disposal procedure, please contact your local
environmental authority!
CAUTION
The cable packs are sensitive to mechanical damage! They must be handled
with care, especially the connectors, in order to avoid damaging them!
Action
CAUTION
Always cut the paint with a knife and grind the
paint edge when disassembling parts. See
the paint or surface on the robot before replacing
parts on page
118.
Set the robot system to MOTORS OFF state.
© Copyright 2004-2018 ABB. All rights reserved.
Note
Cut
This will simplify calibration of the
robot after replacement since no
coarse calibration will be required.
Continues on next page
4 Repair
Continued
169