Switches

/cache{=boolean}
When FALSE (the default), the command causes the controller to
disable the array's array cache. FALSE means:
Disables the read-ahead cache.
Disables the write-back cache.
When TRUE, write cache is enabled, providing maximum
performance.
Notes
When the write cache is enabled, there is a potential for data
loss or corruption during a power failure.
You can enable write cache only if a native operating system's
file system—in Windows, the NTFS or FAT file system—
resides on the array.
If you do not want to enable the stripe set's array cache when
you create it, you can do so later by using the container set
cache command.
/stripe_size{=integer}
Specifies the stripe size for the stripe set. Valid values are
16 KB, 32 KB, and 64 KB.
If you do not specify a value for this switch, it defaults to
64 KB.
/label{=string}
Specifies a label to be assigned to the newly created stripe set.
You can specify a maximum of sixteen characters for the label.
If you do not specify the switch, it defaults to no label. If you
do not specify a label, you can do so later by using the
container set label command.
Note that this label is not the label that displays in Windows
Explorer. The label displayed by Windows Explorer comes
from the label specified with the container format
command.