Adaptec RAID 2810SA Software Reference Manual page 46

Serial ata raid command line interface
Hide thumbs Also See for RAID 2810SA:
Table of Contents

Advertisement

See
page 3-10
for detailed information on the status information
that the command displays in the title bar as it executes the task.
Use the container list command after the container
create mirror command completes execution to display
information about the mirror set, as in the following example:
AAC0>container list
Executing: container list
Num
Total
Oth Stripe
Dr Label Type
Size
Ctr Size
-- ----- ------ ------ --- ------ ------- ------ -------------
0
Mirror 10MB
The following list describes the changes to the display as a result of
using the container create mirror command:
The Type column displays a new array type, which in the
example is Mirror instead of the previously displayed Volume.
The State column displays Normal (instead of a blank) as the
mirror state.
(Note that this column appears only if you specify the /full switch
with the container list command.)
The Scsi C: ID: L column displays the SCSI device IDs for the
two halves of the mirror set.
The Partition Offset:Size column displays the partition offset
and size for the two halves of the mirror set.
If a partition is dead, the ":" (colon) in the Partition Offset:Size
column changes to a "!" (exclamation point). See the disk
remove dead_partitions
more information on dead partitions.
After creating a mirror set, you can manipulate it by using the
container split command to split a mirror set
container unmirror command to unmirror a mirror set
container Commands
Scsi
Partition
Usage
C:ID:L Offset:Size
NTFS
0:02:0 64.0KB:
0:03:0 64.0KB:
7-9) command for
(page
10.0MB
10.0MB
5-7

Advertisement

Table of Contents
loading

Table of Contents