Container Unmirror; Syntax; Parameters; Examples - Adaptec RAID 2810SA Software Reference Manual

Serial ata raid command line interface
Hide thumbs Also See for RAID 2810SA:
Table of Contents

Advertisement

container unmirror

To unmirror a mirror set, resulting in a single-partition volume set
and freespace, use the container unmirror command. Note
that there is no equivalent command for a multilevel array of mirror
sets. To unmirror a multilevel array of mirror sets, use this command
for each underlying mirror set.

Syntax

container unmirror {container}

Parameters

{container}
Specifies the ID number (0 to 63) of the mirror set to unmirror.
You previously created the mirror set by using the container
create mirror or container create mmirror
command.

Examples

Before unmirroring a mirror set, use the container list
command to obtain information about any existing arrays. As the
following example shows, there is one existing array (array 0, a
mirror set) on this controller at the time the mirror set is unmirrored:
AAC0>container list
Executing: container list
Num
Total
Oth Stripe
Dr Label Type
Size
Ctr Size
-- ----- ------ ------ --- ------ ------- --------
0
Mirror 10.0MB
Note that the example eliminates some items in the container
list display so that you can see an example of the State column.
container Commands
Scsi
Usage
C:ID:L
State
-----
NTFS
0:02:0
Normal
0:03:0
5-119