9.18

Z(P).UINI (Station No. Setting of Own Station)

For Universal model QCPUs, the station No. of a normal station (own station) can be set. (
4.6)
For use of the UINI instruction, select "Specify Station No. by Program" in the network parameters. (
Section 6.2)
Internal device
Setting
(System, User)
data
Bit
Word
(S1)
(D1)
[Instruction symbol]
[Execution condition]
Z.UINI
ZP.UINI
*1
" " (double quotation) of the first argument can be omitted.
(1) Setting data
Setting data
"Un"/Un
(S1)
(D1)
*1
Local devices and file registers for each program cannot be used as devices in setting data.
476
Link direct
File
device J\
register
R, ZR
Bit
[Instruction format]
Start contact
Start contact
*1
Start I/O number of the own station's CC-Link IE Controller Network module
(00 to FE
: The higher two digits of the 3-digit I/O number)
H
Start device of the own station that stores control data
(
Page 477, Section 9.18 (2))
The own station's device that is turned on for one scan upon completion of the
instruction
(D1)+1 also turns ON if the instruction execution has failed.
Available devices
Intelligent
function
module device
Word
U\G
Z.UINI
ZP.UINI
Description
Page 136, Section
Page 180,
Constant
Index
register Zn
K, H
$
"Un"
(S1)
(D1)
*1
"Un"
(S1)
(D1)
*1
Data type
String/
Binary 16 bits
Device name
Bit
Others