(2) Control data
Device
Item
Error completion
(S1)+0
type
(S1)+1
Completion status
Own station
(S1)+2
channel
Channel used by
(S1)+3
sending station
Network No. of
(S1)+4
sending station
Sending station
(S1)+5
No.
(S1)+6
(S1)+7
Arrival monitoring
(S1)+8
time
Receive data
(S1)+9
length
(S1)+10
(S1)+11
Clock set flag
(S1)+12
Clock data on
to
error completion
(S1)+15
414
Setting data
b15
to
0
1) Error completion type (bit 7)
Specify the clock data setup status for error completion.
0: Clock data at the time of error completion is not set in the
area starting from (S1)+11.
1: Clock data at the time of error completion is set in the area
starting from (S1)+11.
The instruction completion status is stored.
0: Normal
Other than 0: Error (
Specify the channel of the own station, where receive data are
stored.
(
Page 328, Section 9.2.2 (1))
Stores the channel used by the sending station.
Stores network No. of the sending station.
1 to 239: Network No.
Stores station No. of the sending station.
1 to 120: Station No.
Unused
Unused
Specify the monitoring time required for instruction completion.
If not completed within the time, the instruction is terminated with an
error.
0: 10 seconds
1 to 32767: 1 to 32767 seconds
Stores the receive data size stored in (D1) to (D1)+n.
1 to 960: Receive data size (words)
Unused
The valid or invalid status of the data in the area starting from
(S1)+12 is stored. Data is stored only when 1 is set in the bit 7 of
Error completion type ((S1)+0). Note that the stored value will not be
cleared even after the dedicated instruction is completed.
0: Invalid
1: Valid
Clock data on error completion are stored in BCD format. Data is
stored only when 1 is set in the bit 7 of Error completion type
((S1)+0). Note that the stored value will not be cleared even after the
dedicated instruction is completed.
b15
to
Month (01
to 12
(S1)+12
H
Hour (00
to 23
(S1)+13
H
Second (00
to 59
(S1)+14
H
(S1)+15
Year (00
to 99
), First 2 digits
H
H
b7
to
b0
1)
0
Page 511, Section 10.2)
b8 b7
to
)
Year (00
to 99
), Last 2 digits
H
H
H
Day (01
)
to 31
)
H
H
H
)
Minute (00
to 59
)
H
H
H
Day of week (00
to 06
H
00
(Sun.) to 06
(Sat.)
H
H
Setting range
0000
H
0080
H
1 to 8
0
0
0 to 32767
0
b0
)
H
Setting
*1
side
User
System
User
System
System
System
User
User
User
System
User
System
System