Mitsubishi Electric MELSEC Q Series Reference Manual page 327

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Dedicated
Application
instruction
RRUN
Remote RUN/STOP
(for Q series)
RSTOP
RTMRD
Write/read clock data
on another station
(for Q series)
RTMWR
*1
Not available when the own station or the target station is a safety CPU.
*2
Writing is not allowed from another station to a safety CPU.
*3
When the target station is an A2UCPU(S1), A3UCPU, A4UCPU, A2ASCPU(S1), or A2USCPU(S1), use the CPU
module with the following version or later.
• A2UCPU(S1), A3UCPU, A4UCPU: Version AY (manufactured since July, 1995) or later
• A2ASCPU(S1), A2USCPU(S1): Version CP (manufactured since July, 1995) or later
(b) List of dedicated instructions
Dedicated
Application
instruction
Setting station No.
UINI
(c) List of CC-link dedicated instructions
The following dedicated instructions can be used for transient transmission with a CC-Link IE Controller
Network compatible device.
Dedicated
Application
instruction
RIRD
Read/Write of
another station's data
RIWT
*1
Not available when the own station is a safety CPU.
*2
Not available when the own station or target station is a safety CPU.
(2) Available devices
The following devices are available for the dedicated instructions:
*1
Bit
X, Y, M, L, F, V, B
*1
Word device bit designation is available for bit data.
A bit of a word device is specified with
(Bit No. must be specified in hexadecimal.)
For example, bit 10 of D0 is specified as
Note that, bit designation is not allowed for timers (T), retentive timers (ST) and counters (C).
Instructs a programmable controller on another station to perform remote RUN.
Instructs a programmable controller on another station to perform remote
*1
STOP.
Reads clock data from a programmable controller on another station.
Writes clock data to a programmable controller on another station.
For Universal model QCPUs, the station No. of a normal station (own station)
can be set.
Reads the specified points of data from the target station's device.
Writes the specified points of data to the target station's device.
Internal device
Word
T, ST, C, D, W
Word device
.
D0.A
CHAPTER 9 DEDICATED INSTRUCTIONS
Description
Description
Description
*2
File register
R, ZR
.
.
Bit No.
Reference
section
Page 443,
*1
Section 9.14
Page 451,
Section 9.15
Page 459,
Section 9.16
Page 467,
*2
Section 9.17
Reference
section
Page 476,
Section 9.18
Reference
section
Page 481,
*1
Section 9.19
Page 489,
Section 9.20
Constant
K, H
325
9