(b) Devices used in the program example
• Link special relay (SB) and link special register (SW)
Device
SB0047
SW00A0.1
SW00A0.2
*1
Used when the target station is on a redundant system.
Remark
• For details of link special relay (SB):
• For details of link special register (SW):
• Devices used by the user
Device
M150
M151
M152
M155
(c) SEND instruction settings
Control data settings for the SEND instruction are shown below.
(S1)+0
(S1)+1
(S1)+2
(S1)+3
(S1)+4
(S1)+5
(S1)+6
(S1)+7
(S1)+8
(S1)+9
(S1)+10
(S1)+11
(S1)+12 to
(S1)+15
(S1)+16
(S1)+17
410
Description
Baton pass status (own station)
Baton pass status of station No.2
Baton pass status of station No.3
Description
Control data setting command
Send data setting command
Start contact
Completion device
Device
D350
Execution/Error completion type
D351
Completion status
D352
Channel used by own station
D353
Target station channel
D354
Target station network No.
D355
Target station No.
D356
(Unused)
D357
Number of resends
D358
Arrival monitoring time
D359
Send data length
D360
(Unused)
D361
Clock set flag
D362 to D365
Clock data on error completion
D366
Error-detected network No.
D367
Error-detected station No.
Device
SW01F0.1
SW01F0.2
*1
Page 568, Appendix 1
Page 584, Appendix 2
Device
M156
D350 to
D367
D612
D750 to
D753
Item
Description
Redundant system status (3) of station No.2
Redundant system status (3) of station No.3
Description
Completion status indication device
Control data
Error code storage device
Send data storage device (station No.1)
Set value
0081
(With arrival confirmation, clock data at
H
the time of error completion is set.)
(Set by the system, no setting required)
3
5
1
2 (2 or 3 when the target station is on a
redundant system)
0
5 times
0 (10 seconds)
4 words
0
(Set by the system, no setting required)
*1
*1