4.1.1

Communication using LB/LW

This function allows each station to write data to its own send range area of a link device (LB/LW) to send them to all
other stations on the network.
The link relay (LB) and link register (LW) can send/receive the ON/OFF information and 16-bit data respectively.
(1) Setting each station's send range in LB/LW
Set each station's send range in LB/LW in "LB/LW Setting" of "Network Range Assignment" of the control station.
(
Page 185, Section 6.3.1)
Note that any other area than the own station's send range in LB/LW is the area for the data received from other
stations.
Control station
No.1
Link relay (LB)
LB0
No.1 send range
No.2
No.3
No.4
LB7FFF
Link register (LW)
LW0
No.1 send range
No.2
No.3
No.4
LW1FFFF
*1
For the extended mode (
(2) Setting the link refresh range
Set the range of the transfer between the link devices of the CC-Link IE Controller Network module and CPU
module devices. (
Normal station
Normal station
No.2
No.3
No.1
No.2 send range
No.3
No.3 send range
No.4
No.1
No.2 send range
No.3
No.3 send range
No.4
Page 181, Section 6.2 (1))
Page 69, Section 4.1.3)
Normal station
No.4
No.1
No.1
No.2
No.2
No.3
No.4
No.4 send range
No.1
No.1
No.2
No.2
No.3
No.4
No.4 send range
CHAPTER 4 FUNCTIONS
Up to 32K*
1
link
points are available
per station.
Up to 128K*
1
link
points are available
per station.
61
4