Mitsubishi Electric MELSEC Q Series Reference Manual page 603

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

No.
Name
SW0170
Transient error
to
detection status of
SW0177
each station
SW0180
Power supply status of
to
each station
SW0187
Stores whether the transient transmission error is detected or not in each
station from power-on to the present.
The transient error detection status of own station is cleared when Clear
transient transmission error counter (SB000A) is turned ON.
Turn ON Clear transient transmission error counter (SB000A) at other station
side when clearing the transient error detection status of other station.
0: Error not detected
1: Error detected
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0170 16 15 14 13 12 11 10
SW0171
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0172
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0173
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0174
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0175
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0176
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0177
-
-
-
-
-
Each number in the table represents station No.
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
Stores the external power supply status of the CC-Link IE Controller Network
module on each station. (Including own station)
0: No external power supplied
1: External power supplied
This register is always OFF when the CC-Link IE Controller Network module
does not have the external power supply function.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0180 16 15 14 13 12 11 10
SW0181
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0182
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0183
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0184
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0185
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0186
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0187
-
-
-
-
-
Each number in the table represents station No.
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
• The reserved station and the station No. later than the largest one are
excepted.
Description
9
8
7
6
5
4
3
-
-
- 120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
-
-
- 120 119 118 117 116 115 114 113
APPENDICES