 Ethernet
Users have to select the station address of the AH500 series motion control
module connected to the computer in the Station drop-down list box. If the station
address selected is 0, a broadcast communication will be carried out. The users
also have to select the IP address created in COMMGR in the IP Address
drop-down list box.
12.5
Modbus Communication
 Setting an Ethernet IP address
The default Ethernet IP address of an AH500 series motion control module is 192.168.0.100.
Users can change the Ethernet IP address of an AH500 series motion control module by
means of SR808 and SR809, or by means of the motion control function block T_TcpIPAddr.
 An AH500 series motion control module can function as a Modbus TCP slave.
If users connect an AH500 series motion control module by means of Ethernet, the AH500
series motion control module can function as a Modbus TCP slave. If an AH500 series motion
control module is connected to a human-machine interface, the steps of setting the
human-machine interface will be as follows.
1. Click Configuration... on the Options menu.
2. Click the Main tab, and then select DOP-B10E615 65536 Colors in the HMI Type
drop-down list box.