3. Number of pulses generated by the manual pulse generator for the axis specified
HW
SR1047+100*N
[Description]
The value in (SR1047+100*N, SR1046+100*N) indicates the number of pulses generated by
the manual pulse generator for the axis specified. If the pulses generated by the manual pulse
generator for the axis specified are clockwise pulses, the value in (SR1047+100*N,
SR1046+100*N) will increase. If the pulses generated by the manual pulse generator for the
axis specified are counterclockwise pulses, the value in (SR1047+100*N, SR1046+100*N) will
decrease.
The value in (SR1047+100*N, SR1046+100*N) does not vary with the values in SR1042+100*N
and SR1043+100*N.
4. Response speed of the manual pulse generator for the axis specified
HW
[Description]
If the response speed set is high, the pulses output happen almost at the same time as the
pulse input by the manual pulse generator used.
If the response speed set is low, the pulses output follows the pulses input by the manual pulse
generator used.
Setting value
≧5
4
3
2
1 or 0
(1+N)
(1+N)
-
Response speed
4 ms (Initial value)
32 ms
108 ms
256 ms
500 ms