Cann Error Count Register (Cnerc) - NEC Renesas V850/SC1 User Manual

32-bit single-chip microcontrollers
Hide thumbs Also See for Renesas V850/SC1:
Table of Contents

Advertisement

19.5.22 CANn error count register (CnERC)

The CnERC register indicates the count values of the transmission/reception error counters.
This register is read-only in 16-bit units.
The C2ERC register is valid only in models µ PD703089Y and 70F3089Y.
After reset: 0000H
15
CnERC
REC7
(n = 1, 2)
7
TEC7
REC7 to REC0
• This reflects the current status of the reception error counter.
• The count value is defined by the CAN protocol.
TEC7 to TEC0
• This reflects the current status of the transmission error counter.
• The number of counts is defined by the CAN protocol.
CHAPTER 19
FCAN CONTROLLER (V850/SC3)
R
Addresses: C1ERC: xx3FFC56H
14
13
REC6
REC5
6
5
TEC6
TEC5
0 to 255
Number of reception error counts
0 to 255
Number of transmission error counts
User's Manual U15109EJ3V0UD
C2ERC: xx3FFC96H
12
11
10
REC4
REC3
REC2
4
3
2
TEC4
TEC3
TEC2
Reception error counter
Transmission error counter
9
8
REC1
REC0
1
0
TEC1
TEC0
617