The Stinger CR cooling unit has two status lights on the front to indicate the
operating status of the cooling unit and the enclosure ventilation fan. The status
indicted by these lights is described in Table 3-7.
Table 3-7. Cooling unit status light
Condition
On green
On red
Blinking green

Power supply status lights

When lit, the power supply status light indicates that it is providing -48Vdc power to
the Stinger CR unit. You can use the test points to measure the -48Vdc output and
verify that it is within tolerance (±10%).
The status lights for both the ±190Vdc power supply and the -48Vdc power supply
are identical. The STATUS light is lit if the power supply is providing internal -48Vdc
power for the unit.
The Stinger CR ±190Vdc power supply is shown in Figure 3-35.
Figure 3-36. The Stinger CR ±190Vdc power supply

What's next

When you finish physically installing the Stinger CR ATM DSLAM unit you can
proceed to the next chapter.
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Indicates
The fan has power.
The fan is in a fault state.
The fan is initializing.
Input power connector
POWER INPUTS
+190V
-190V
Enclosure and Component Installation
Status light
Test points
V.CHECK
STATUS
-48V
0V
COMPACT REMOTE POWER SUPPLY

What's next

Locking
screw
3-47