Table 6-1. Compact Remote alarm events
Alarm event definition
external-fan-failure
input-relay-closed
input-relay-open
over-temperature-relay
door-open

Sample alarm for remote shelf 3 state change

The following commands set an alarm for a change in status of shelf 3:
HOST> new alarm shelf-3
HOST> set enabled = yes
HOST> set event = remote-shelf-state-change
HOST> set physical-address shelf = shelf-3
HOST> write -f
If the alarm is triggered (for example, if shelf 3 becomes unavailable), an emergency
log message is displayed. For example:
LOG emergency, Shelf 1, Controller-1, Time: 14:26:35--
Wed Sep 17 14:26:35 2000 - ALARM: Remote Shelf { 3 } Alarm is: Active
The following alarm command shows that an alarm has been set and the remote shelf
is down:
HOST> alarm -s
Remote Shelf Down
When the shelf changes state again, for example, when it comes up or is disabled in
the remote-shelf-config profile, the alarm is cleared. for example:
LOG emergency, Shelf 1, Controller-1, Time: 14:28:16--
Wed Sep 17 14:28:16 2000 - ALARM: Remote Shelf { 3 } Alarm is: Cleared
HOST> alarm -s
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Event on remote shelf that triggers alarm
A sensor on the remote shelf indicates failure of the
external fan unit. The failed status is shown in the
external-fan-unit-failed setting of the
remote-shelf-stat profile.
Contact-closure sensors on the remote shelf indicate
closure. The status is shown in the contact-closure[N]
setting of the remote-shelf-stat profile.
Contact-closure sensors on the remote shelf indicate
loss of contact closure. The status is shown in the
contact-closure[N] setting of the remote-shelf-stat
profile.
A temperature sensor on the remote shelf indicates an
over-temperature condition. The status is shown in the
over-temperature setting of the remote-shelf-stat
profile.
A sensor on the remote shelf indicates that the door has
been opened.The status is shown in the door-open
setting of the remote-shelf-stat profile.
Type
Address
{ 3 }
Type
Address
Hosted System Management
Monitoring the status of remote shelves
State
Active
State
6-9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stinger Compact Remote and is the answer not in the manual?

Table of Contents