Hosted System Management
Monitoring the status of remote shelves
Sample alarm for input-relay closure status on any remote shelf
The following commands configure an alarm for input-relay closure on any remote
shelf in a hosted system:
HOST> new alarm closed
HOST> set enabled = yes
HOST> set event = input-relay-closed
HOST> write -f
HOST> new alarm open
HOST> set enabled = yes
HOST> set event = input-relay-open
HOST> write -f
If one of the alarms is triggered, the alarm action takes effect, and the
remote-shelf-stat profile is updated. In addition, the status is accessible in the
output of the alarm -s command. For example, the following output shows contact
closure on shelf 2:
HOST> alarm -s
Input Relay Closed
Input Relay Closed
Input Relay Closed
Input Relay Closed
Input Relay Closed
Input Relay Closed
Input Relay Closed
Sample alarm for internal fan failure on shelf 2
The next commands set an alarm for failure of the internal fan unit on shelf 2:
HOST> new alarm fan
HOST> set enabled = yes
HOST> set event = fan-failure
HOST> set physical-address shelf = shelf-2
HOST> write -f
If the alarm is triggered, the alarm action takes effect, and the remote-shelf-stat
profile is updated. In addition, the status is accessible in the output of the alarm -s
command. For example:
HOST> alarm -s
Fan Failure
6-10
Type
Address
{ 2 0 1 }
{ 2 0 2 }
{ 2 0 3 }
{ 2 0 4 }
{ 2 0 5 }
{ 2 0 6 }
{ 2 0 7 }
Type
Address
{ shelf - 2 }
The Stinger® Compact Remote ATM DSLAM Getting Started Guide