To connect a management workstation to the Stinger unit using an indirect Ethernet
connection:
1
Connect one end of the Ethernet cable to the Ethernet RJ-48 port on the control
module.
2
Connect the other end of the Ethernet cable to the local LAN.
3
Ensure that the management workstation has connectivity to the LAN on which
the unit resides.
4
Ensure the Ethernet transceivers are connected properly to the network.
Diagnostic port
This port is present on the COP, IP2000, and control modules. However, it is only
used to access the local command interface for configuration and management on
stand-alone Stinger CR ATM DSLAM units, using the IP2000 module or control
module.
Note
This interface is not used on Stinger CR ATM DSLAM units that are being
installed with a COP for hosted operation. The TAOS software installed on these units
is set to operate the unit in hosted mode by default. Additional configuration of the
ADSL lines and ATM connection is accomplished from the host unit.
Figure 3-27 shows an serial connection from a console terminal to the Diagnostic
port of an IP2000 module in a Stinger CR ATM DSLAM unit.
Figure 3-27. Serial management connection for a stand-alone Stinger CR ATM DSLAM
To connect a console terminal to a Stinger CR ATM DSLAM unit, connect one end of
a shielded straight-through cable to the diagnostic port (DIAG PORT) on the IP2000
or control module. Then connect the other end of the cable to the serial port on the
console device.
The diagnostic port on the IP2000 or control module consists of a female DB-9
connector. Examine the serial connector of your PC or dumb terminal to ensure that
your shielded straight-through cable has the proper connectors. If needed, you can
use DB-9-to-DB-25 converters or gender converters to complete this connection.
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
COOLIN G UNIT
COOLIN G UNIT
TUS
ST
STATUS
EXTER NAL
EXTER NAL
INTERN AL
INTERN AL
RED - FAULT
GREEN - A
GREEN - ACTIVE
- INITIALIZ ING
- INITIALIZ ING
BLINKING GREEN
BLINKING GREEN
CT REMO TE
TE
COMP ACT REMO
COMP
COP
3
3
LIM
LPM
LIM
2
2
1
LPM
LIM
LPM
1
10
LINK
100
ACT
Gig. E
ACT
LINK
3
COP
LIM
LPM
3
2
2
LIM
LPM
LIM
1
LPM
1
POWE R INPU
WER INPU TS
TS
V.CHE CK
.CHE CK
PO
0V
-48V
STATU S
ST
TUS
+190V
WER SUP PLY
PL
TE POW ER SUP
-190V
PO
COM PAC T REM
CT REM OTE
O
COM P
Enclosure and Component Installation
Physical connections to the components
Diagnostic
port
LIN K
10
ACT
100
Gig . E
ACT
LINK
To console
serial port
3-35
Need help?
Do you have a question about the Stinger Compact Remote and is the answer not in the manual?