Protection Block Port Numbering Vs. Taos Port Indexing; Figure C-5 Protection Block Port Assignments - Lucent Technologies Stinger Compact Remote Getting Started Manual

Atm dslam
Table of Contents

Advertisement

Cables and Connectors
Cabling for the 48-port LPM with splitters

Protection block Port numbering vs. TAOS port indexing

Each LIM/LPM pair supports 48 ports. These ports are referred to by the TAOS
software as ports 1 through 48 indexed by the shelf and slot in which the LIM that
supports these ports is installed. The TAOS software refers to these ports as {shelf-n
slot-1 1} through {shelf-n slot-1 48}. Lines through P1 and P2 are identified by TAOS
as ports {shelf-n slot-1 1} through {shelf-n slot-1 48}. Lines through P3 and P4 are
identified by TAOS as ports {shelf-n slot-2 1} through {shelf-n slot-2 48}. Lines
through P5 and P6 are identified by TAOS as ports {shelf-n slot-3 1} through {shelf-n
slot-3 48}.
An illustration on the enclosure door shows the ports for all three slots numbered
continuously on the protection blocks. Figure C-5 shows this port numbering system.
Protectors shown as IN are associated with pairs that bring analog POTS service into
the Stinger CR from the central office. Protectors shown as OUT are associated with
the pairs that carry combined ADSL/POTS service to individual subscribers.
Figure C-5.
C-6
Protection block port assignments
LPM 1
P1
OUT
OUT
OUT
OUT
OUT
1
11
21
31
41
OUT
OUT
OUT
OUT
OUT
2
12
22
32
42
OUT
OUT
OUT
OUT
OUT
3
13
23
33
43
OUT
OUT
OUT
OUT
OUT
4
14
24
34
44
OUT
OUT
OUT
OUT
OUT
5
15
25
35
45
OUT
OUT
OUT
OUT
OUT
6
16
26
36
46
OUT
OUT
OUT
OUT
OUT
7
17
27
37
47
OUT
OUT
OUT
OUT
OUT
8
18
28
38
48
OUT
OUT
OUT
OUT
PWR
9
19
29
39
OUT
OUT
OUT
OUT
PWR
10
20
30
40
P2
IN
IN
IN
IN
IN
1
11
21
31
41
IN
IN
IN
IN
IN
2
12
22
32
42
IN
IN
IN
IN
IN
3
13
23
33
43
IN
IN
IN
IN
IN
4
14
24
34
44
IN
IN
IN
IN
IN
5
15
25
35
45
IN
IN
IN
IN
IN
6
16
26
36
46
IN
IN
IN
IN
IN
7
17
27
37
47
IN
IN
IN
IN
IN
8
18
28
38
48
IN
IN
IN
IN
PWR
9
19
29
39
IN
IN
IN
IN
PWR
10
20
30
40
*
The analog modem pair in stand-alone units with a
control module that has an internal modem, this
protector has no connection in other units.
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
LPM 2
LPM 3
P3
P5
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
49
59
69
79
89
97
107
117
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
50
60
70
80
90
98
108
118
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
51
61
71
81
92
99
109
119
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
52
62
72
82
92
100
110
120
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
53
63
73
83
93
101
111
121
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
54
64
74
84
94
102
112
122
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
55
65
75
85
95
103
113
123
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
56
66
76
86
96
104
114
124
OUT
OUT
OUT
OUT
OUT
OUT
OUT
PWR
57
67
77
87
105
115
125
OUT
OUT
OUT
OUT
NC
OUT
OUT
OUT
58
68
78
88
106
116
126
P4
P6
IN
IN
IN
IN
IN
IN
IN
IN
49
59
69
79
89
97
107
117
IN
IN
IN
IN
IN
IN
IN
IN
50
60
70
80
90
98
108
118
IN
IN
IN
IN
IN
IN
IN
IN
51
61
71
81
91
99
109
119
IN
IN
IN
IN
IN
IN
IN
IN
52
62
72
82
92
100
110
120
IN
IN
IN
IN
IN
IN
IN
IN
53
63
73
83
93
101
111
121
IN
IN
IN
IN
IN
IN
IN
IN
54
64
74
84
94
102
112
122
IN
IN
IN
IN
IN
IN
IN
IN
55
65
75
85
95
103
113
123
IN
IN
IN
IN
IN
IN
IN
IN
96
56
66
76
86
104
114
124
IN
IN
IN
IN
NC
IN
IN
IN
57
67
77
87
105
115
125
IN
IN
IN
IN
NC
IN
IN
IN
58
68
78
88
106
116
126
OUT
OUT
127
137
OUT
OUT
128
138
OUT
OUT
129
139
OUT
OUT
130
140
OUT
OUT
131
141
OUT
OUT
132
142
OUT
OUT
133
143
OUT
OUT
134
144
OUT
*
135
OUT
NC
136
IN
IN
127
137
IN
IN
128
138
IN
IN
129
139
IN
IN
130
140
IN
IN
131
141
IN
IN
132
142
IN
IN
133
143
IN
IN
144
134
IN
NC
135
IN
NC
136

Advertisement

Table of Contents
loading

Table of Contents