Cables and Connectors
Cabling for the 48-port LPM with splitters
LPM connectors
The 48-port LPM with splitters has three 64-pin connectors, labeled P2801, P2802,
and P2803. This connector is detailed in Figure C-2.
Figure C-2.
On each LPM, the bottom connector (P2801) provides 32 connections for subscriber
voice-over-DSL connections. The top connector (P2803) provides 32 connections for
analog POTS service from the telephone switch. The connector in the middle (P2802)
provides the remaining 16 voice-over-DSL and 16 POTS connections.
LPM connections and protection blocks
There are three pairs of protection blocks in the Stinger CR ATM DSLAM enclosure.
Each pair of protection blocks is pre-wired with three 64-pin connectors for
connection to one of the LPMs in the Stinger CR ATM DSLAM card cage.
LPM cables
Each pair of protection blocks has a set of three cables for connection to the 64-pin
connectors on an LPM. These cables and connectors are illustrated in Figure C-3.
Note
Figure C-3 is not an exact representation of the length or position of the cables
connected to the protection blocks.
C-4
LPM 64-pin connector
64
33
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
32
1