COMMISSIONING

7.3.4.13 Density configuration

Name
[Displacer volume]
[Displacer weight]
[Density scan direction]
[Number of density
measurement points]
[Density interface
profile start level]
[Density interface
profile stop level]
[Interface profile]
[Number of tank profile
drum balance points]
[Density tank profile
start distance]
82
Value Range
<Scan direction up>
<Scan direction down>
<1..50>
<1..32>
Service Manual
954 SmartServo FlexLine
Default Value
Explanation
<110>
The displacer volume.
<223>
The displacer weight in air.
<Scan direction
Determines whether the
down>
density measurements are
performed downwards (from
e.g. product level) or
upwards (from e.g. the
bottom). See also start and
stop level entities.
<10>
Determines over how many
points (levels) the interface
or tank profile density
measurements are done.
<-999.9999>
Determines the interface
profile start level from where
the density measurements
are performed.
<-999.9999>
Determines the interface
profile stop level until where
the density measurements
are performed.
This command starts a
interface profile density
measurement. The density
measurement positions are
equally distributed from the
range:
[Density IP start level] until
[Density IP stop level] with
the number of points defined
by [Number of density
measurements (max 50)].
<10>
Determines the number of
points over the drum
circumference at a level
position used for the tank
profile density measurement.
<0.3>
Determines the tank profile
start level from where the
density measurements are
performed. This means the
product level minus this start
distance.