COMMISSIONING
Name
[Alarm test enable]
[Alarm test]
[Function identification]
Name
[Maximum water capacity]
[Minimum water capacity]
[Water probe bottom position]
[Upper reference level]
Part No.: 4417340 Revision 1
Explanation
Enables (if activated, see
next listed entity) the
simulation of one of the 4
alarms for a minute, by
simulating the actual
measured Primary Value is
below or above the alarm
threshold.
Activates and selects at the
same time the Alarm test (if
enabled with the
enable]
listed before, and the
4 alarm thresholds are
properly set).
The current module's
function name. This
function is visible on the
HART SmartView
display.
Water Level (for 766/768 Combi probes and 765 Water probe only)
The following entities must be set by Engauge or HART
SmartView for a correct functioning of the FII-VT module in an
instrument.
Explanation
The maximum capacity
when the probe is fully
submerged in water (in pF)
The minimum capacity
when the probe is not
submerged in water (in pF)
The offset to the water
probe zero point in relation
with the tank zero point
The distance from tank zero
point to upper reference
point; is used for water
ullage calculation
Service Manual
954 SmartServo FlexLine
Value Range
<enable>
<disable>
[No Alarm]
[High High alarm]
[Alarm test
[High Alarm]
[Low Alarm]
[Low Low alarm]
13 characters
Value Range
floating point number:
<-x.x .. +x.x>
floating point number:
<-x.x .. +x.x>
floating point number:
<-x.x .. +x.x>
floating point number:
<-x.x .. +x.x>
Default
<disable>
<No Alarm>
<Vapour temp.>
Default
<20000>
<20000>
<80>
<80>
125