Honeywell FlexLine SmartServo 954 Service Manual page 89

Servo-based level gauge
Hide thumbs Also See for FlexLine SmartServo 954:
Table of Contents

Advertisement

COMMISSIONING
7.3.4.12 Advanced Configuration
Name
[Displacer area]
[Integration time 1]
[Integration time 2]
[Integration time 3]
[Wire weight per
unit of length]
[Wire temperature
coefficient]
[Wire cross
sectional area]
[Elasticity
coefficient]
Drum blind length
Part No.: 4417340 Revision 1
Value Range
Default Value
<0.0065>
<2>
<2>
<2>
<0.00025>
<1.2E-05>
<3.1416E-08>
<2E+11>
<0.0>
Service Manual
954 SmartServo FlexLine
Explanation
The displacer area must be
entered at the point where
the displacer touches the
interface when the control
loop is in balance.
Used to filter out (fast)
fluctuations of the resp.
interfaces 1, 2 and 3.
This entity is used to
compensate the set point
with the weight of the wire.
Determines the temperature
expansion coefficient of the
wire (according to a related
table)
Determines the cross
sectional area of the wire.
Determines the elasticity
coefficient of the wire
(according to a related table)
Determines the non used
part of the wire on the drum
when the wire length > 50m
till 150m. concerning related
calculations.
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents