COMMISSIONING
Name
[Measured
frequency status]
[Measure frequency
F0]
[Measure frequency
F1]
[Measure frequency
F2]
[Measure frequency
F3]
[Measured
frequency]
[Measured weight]
[Measured
compensated
weight]
[Measured
frequency
continuously]
[Go up]
90
Value Range
Default Value
<active, not
active>
Service Manual
954 SmartServo FlexLine
Explanation
This entity gives the status
whether the F0..F3 are being
measured.
This command will measure the
frequency with the actual
attached weight of 25 g. The
result is placed in entity
[frequency 0].
This command will measure the
frequency with the actual
attached weight of 100 g. The
result is placed in entity
[frequency 1].
This command will measure the
frequency with the actual
attached weight of 175 g. The
result is placed in entity
[frequency 2].
This command will measure the
frequency with the actual
attached weight of 250 g. The
result is placed in entity
[frequency 3].
This entity holds the measured
frequency after the [Measure
frequency] command has been
given.
This entity holds the measured
weight of the displacer after the
[Measure frequency] command
has been given.
This entity holds the measured
weight of the displacer minus
the wire weight after the
[Measure frequency] command
has been given.
Shows the continuous measured
frequency
This command will let the
displacer run up continuously. It
can only be activated during
maintenance mode.
The command can be
interrupted by Freeze or Go
down command.
No wire tension check!