Wire Weight; Unbalance - Honeywell FlexLine SmartServo 954 Service Manual

Servo-based level gauge
Hide thumbs Also See for FlexLine SmartServo 954:
Table of Contents

Advertisement

COMMISSIONING
7.7.1.1

Wire weight

Entity name
[Wire weight per unit of length]
7.7.1.2

Unbalance

238
The wire weight compensation requires one configuration parameter.
This parameter is automatically set correctly when the correct
[Measuring range and wire type]
When
<
No measuring range selected>
selected the wire weight needs to be set manually:
Default Value
< 0.00025 [kg/m] >
The unbalance compensation needs a table with the measured
unbalance. This table is automatically generated when performing a
balance test.
Note: Whenever the drum has been (temporarily) removed from the
gauge or the drum is replaced by another one, a new balance test must
be performed to update the unbalance table.
Service Manual
954 SmartServo FlexLine
is chosen (refer to section
or
<Other measuring range or wire type>
Explanation
Wire weight in kg per meter. The default value
is for stainless steel 316.
Part No.: 4417340 Revision 1
7.4)