COMMISSIONING
Name
[Water density dip]
[Density water dip]
[Density
compensations]
84
Value Range
<enable>
<disable>
Service Manual
954 SmartServo FlexLine
Default Value
Explanation
This command first searches
for the water level and after
that performs a density
measurement upwards. And
then returns to the default
operation mode.
This command first performs
a density measurement
downwards and after that
searches for the water level.
And then returns to the
default operation mode.
<enable>
Enable or disable the
<enable>
following compensations for
<disable>
the density:
<enable>
-Tilt
Calibrates the density
measurement for tilt of the
gauge
-Unbalance
Compensates density for the
unbalance of the drum
-Unused
-Volume
Compensates density for
hydrostatic deformation of
the displacer
Part No.: 4417340 Revision 1