COMMISSIONING

7.3.4.16 Servo auto test

Name
[SAT upwards]
[SAT downwards]
[Autonomous SAT enable]
[SAT raise height up]
[SAT raise height down]
[SAT interval time]
[SAT sample interval]
[SAT trip distance]
[SAT weight limit up]
[SAT weight limit down]
[SAT immersed weight
limit]
Part No.: 4417340 Revision 1
Value Range
<SAT disable>
<SAT enable up>
<SAT enable up and
down>
Service Manual
954 SmartServo FlexLine
Default Value
Explanation
With this command a
manual SAT upwards
can be performed.
With this command a
manual SAT downwards
can be performed.
<SAT enable up>
Determines whether the
SAT is disabled, or
enabled for upward
movements, or enabled
for upward and
downward movements.
<0.02>
Determines the upward
raise height.
<0.02>
Determines the
downward raise height.
<60>
Determines how often
the SAT is performed.
<60>
Determines the time
period for checking if
there is a stable level.
<0.003>
Determines if the level
can be called stable.
That means if the
previous measurement
level compared to the
current measurement is
still within the trip
distance.
<0.005>
Determines the
maximum weight
change if the displacer
is raised.
<0.005>
Determines the
maximum weight
change if the displacer
is immersed.
<0.18>
Determines the
maximum total weight if
the displacer is
immersed.