Level Status Bytes; Density Status Byte - Honeywell FlexLine SmartServo 954 Service Manual

Servo-based level gauge
Hide thumbs Also See for FlexLine SmartServo 954:
Table of Contents

Advertisement

DENSITY OPTION
level status byte 0
Bit
Description
0
general fail / default setting
1
no valid product level
2
level / trajectory exceeds motor
limit high level
3
level / trajectory exceeds motor
limit low level
4
0
5
0
6
1
7
0
Bit
Description
0
general fail / default setting
1
measurement not completed
2
0 = Tank Profile, 1 = Interface Profile
3
no measuring point or measuring point out of range
4
level / trajectory exceeds motor limit level
5
0
6
1
7
0
Part No.: 4417340 Revision 1

Level status bytes

Density status byte

Service Manual
954 SmartServo FlexLine
level status byte 1
Bit
Description
0
trajectory exceeds level product level;
[Tank profile start distance]
only)
1
density trajectory stops below stop level
(TP only)
2
no valid start or stop levels (IP only)
3
0
4
0
5
0
6
1
7
0
too small (TP
283

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents