Figure 7-43

Protection and detection settings

Part No.: 4417340 Revision 1
The same procedure must be followed for all different levels, with for
instance an interval of 1 meter. Then the following table is obtained:

Example of hydrostatic deformation figures

Level
Deformation
[m]
[mm]
0
0
1
0.01
2
0.03
3
0.07
4
0.13
5
0.20
6
0.29
7
0.40
The values in this table are the basis for the graph in

Example of hydrostatic deformation correction

Calculate a regression line from the level where the tank shell
deviation is approximately 0.5 mm. In this example, the regression line
is calculated from 8 meters level till the maximum level.
Then, the [Hydrostatic deformation factor] becomes: 0.3869 mm/m.
The [Hydrostatic deformation level] is the point where the regression
line crosses the X-axis; in this example at 8.1435 m.
For proper functioning the servo gauge has several protection
mechanisms implemented. For normal operation these protection
Service Manual
954 SmartServo FlexLine
Level
Deformation
Level
[m]
[mm]
[m]
8
0.54
9
0.69
10
0.88
11
1.09
12
1.32
13
1.59
14
1.90
21.945
15
2.25
Deformation
[mm]
16
2.64
17
3.08
18
3.57
19
4.17
20
4.71
21
5.36
6.04
Figure 7-43