Density - Honeywell FlexLine SmartServo 954 Service Manual

Servo-based level gauge
Hide thumbs Also See for FlexLine SmartServo 954:
Table of Contents

Advertisement

COMMISSIONING
7.3.4.8

Density

Name
[Primary value]
[Primary value gain]
[Primary value offset]
[Secondary value]
[High high alarm]
[High alarm]
[Low alarm]
[Low low alarm]
[Alarm hysteresis]
[Alarm test enable]
[Alarm test]
[Kill measurement]
[Manual overwrite]
[Resurrect]
[Manual overwrite status]
[Density data]
74
Value Range
Service Manual
954 SmartServo FlexLine
Default Value
Explanation
Shows the calculated
density value after a
density profile or tank
profile command.
Fields, see product
level
See product level
See product level
N.A.
See product level
See product level
See product level
See product level
See product level
See product level
See product level
During a density
measurement, a
maximum of 50
density/level points will
be presented with the
following fields:
<index> the
density/level point
number.
<density status byte>
<density value>
<level status byte 1>
<level status byte 2>
<level value>
(status bytes according
to items [D0] and [R0])
Part No.: 4417340 Revision 1