Maintenance-Object Repair Procedures
Table 8-45. Test #161 Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
2. Use the status station extension command to determine the service
3. If the port is active, wait until it is idle before testing. Retry the command at
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1018
ABORT
Administration has disabled the test. The default for the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test 48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
2. Change the
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
The reflective loop-around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can also
be off-board.
1. Since a line seizure may affect the test, repeat the test at 1-minute
2. Using the test board UUCSS short command, run circuit pack tests to
3. Resolve any problems on the Tone Generator or the Tone Detector circuit.
4. If the Tone Generator and Tone Detector circuits are functioning properly,
5. If the test still fails, replace the analog line circuit pack.
PASS
The port provides an analog transmission path to the station equipment.
Investigate user-reported troubles on this port by running other port tests, by
examining station wiring, or by inspecting the station.
8-118
Issue 1 May 2002
extension.
state of the port.
1-minute intervals up to 5 times.
station extension.
Test?
field on the station form to y.
intervals up to 5 times.
check the Tone Generator and the Tone Detector circuits on the IPSIs or
the Tone Generator/Tone Detector circuit packs.
determine whether a voice terminal is connected and wired properly.
Resolve any problems found.
field on the
Test?
Continued on next page