Avaya S8700 Maintenance Manual page 793

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ANL-24-L (24-Port Analog Line)
Table 8-29. Test #35 Battery Feed Test — Continued
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call. This result is also reported for the system's
Music-On-Hold port when it is off-hook, which it usually is.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
2. Use the status station command to determine the service state of the
3. If the port is active, wait until it is idle, and retry the command at 1-minute
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018
ABORT
The test has been disabled via administration. The default for the
on the station form is y. Determine why this field has been set to n on this
station (this may be due to the ringing application test 48, that can be customer
or terminal disturbing).
1. To enable the test for a particular station being tested, enter change
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
2. If the port is not a TTI port, escalate the problem. If both commands
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The port's battery feed chip is unable to supply sufficient power to the terminal
equipment. This could be a marginal test, and the terminal equipment may be
operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
555-233-143
extension.
port.
intervals up to 5 times.
station extension and set the
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t
for the port).
indicate that the port is a TTI port, the abort is correct for the test, and no
action is necessary.
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
Test?
field on the station from n to y.
Continued on next page
Issue 1 May 2002
Test
field
8-71

Advertisement

Table of Contents
loading