ADX16D-P (16-Port AUDIX Digital Port)
Table 8-11. Test #13 Voice and Control Channel Local Loop Test — Continued
Error
Test
Code
Result
Description / Recommendation
None
FAIL
The test failed for reasons external to the AUDIX.
1. Run circuit pack tests to check the IPSI Tone Generator circuit or Tone
2. Resolve any problems detected on the Tone Generator circuit or Tone
3. If both circuit packs are functioning properly and the test still fails, replace
PASS
Voice and Control Channel Local Loop test passed. Every channel are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to 10
2. If complaints still exist, examine the connections.
555-233-143
Generator circuit pack and the IPSI Tone Detector circuit or Tone Detector
circuit pack using test board UUCSS s.
Detector circuit.
the AUDIX (see caution at the beginning of this section).
times, and see whether it continues to pass.