Avaya S8700 Maintenance Manual page 783

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ANL-16-L (16-Port Analog Line)
Table 8-25. Test #161 Loop-Around Test — Continued
Error
Test
Code
Result
1018
ABORT
2000
ABORT
2100
ABORT
FAIL
555-233-143
Description / Recommendation
The test has been disabled by administration. The default for the
field on the station form is y. Determine why this field has been set to "n" on
this station (this may be due to the ringing application Test #48, which can be
customer or terminal disturbing).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the Test? field on the station to y.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
The reflective loop around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can
also be off-board.
1. Since the test may be affected by a line seizure, repeat the test at
1-minute intervals up to 5 times.
2. Run circuit pack tests to check the IPSI Tone Generator circuit or Tone
Generator circuit pack and the IPSI Tone Detector circuit or Tone
Detector circuit pack by using the test board UUCSS short command.
3. Resolve any problems on the Tone Generator circuit or the Tone
Detector circuit.
4. If the Tone Generator and Tone Detector circuits are functioning properly
and the test still fails and a voice terminal is connected and wired
properly, replace the analog line circuit pack.
Test?
Continued on next page
Issue 1 May 2002
8-61

Advertisement