Avaya S8700 Maintenance Manual page 779

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ANL-16-L (16-Port Analog Line)
Table 8-23. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Test
Code
Result
Description / Recommendation
7
FAIL
The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
8
FAIL
This does not indicate a hardware problem. There may be an internal software
error. The ringer update failed.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, or by examining the station.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the list config
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
555-233-143
command and resolve problems.
board command.
This should re-establish the linkage between the internal ID and the port. If
not, verify that a valid board is inserted.
Continued on next page
Issue 1 May 2002
8-57

Advertisement

Table of Contents
loading