Avaya S8700 Maintenance Manual page 108

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Alarms, Errors, and Troubleshooting
2. Enter status pnc at the S8700 Multi-Connect SAT. This display tells you
which TN230X board is active in a duplicated system and how many
alarms (if any) of each severity level have been logged for the board.
Figure 4-10
status pnc
A-PNC
Mode:
State of Health:
Inter PN Index:
Major Alarms:
Minor Alarms:
Warning Alarms:
Figure 4-10. Screen output for status pnc command
3. Enter either list configuration UUC (for the carrier where the ATM-EI
packs reside) or display circuit-packs cabinet (non-control cabinet) at
the S8700 Multi-Connect SAT. This command tells you in more detail what
boards are in which slots in each cabinet and carrier. Verify that the
TN230Xs are physically located in the slots indicated on the display.
Figure 4-11 on page 4-35
command.
circuit-packs 2 command.
4-34
Issue 1 May 2002
shows the output from this command.
PORT-NETWORK CONNECTIVITY
Duplicated? no
Software Locked?
Standby Busied?
Standby Refreshed?
Interchange Disabled?
active
0
0
0
shows the output for the display circuit-packs 1
Figure 4-12 on page 4-36
B-PNC
Mode:
State of Health:
Inter PN Index:
Major Alarms:
Minor Alarms:
Warning Alarms:
shows the output for the display
555-233-143