Maintenance-Object Repair Procedures
Table 8-93. ATM Board Reset (#1256)
Error
Test
Code
Result
Description / Recommendation
1386
ABORT
No Active EAL to the board. This error applies only if the board under test is in
EPN. Check the error logs for SYS-LINK errors against the EPN where the
ATM-EI resides, and take appropriate diagnostic action for the SYS-LINK.
1015
ABORT
This test cannot be run because the ATM-EI circuit pack has not been busied
out.
1. Busyout the ATM circuit pack, then repeat the test board UUCSS long
1407
ABORT
1. Perform a PNC Interchange
2. Try to reset the board again.
None
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort escalate the problem.
2000
ABORT
Did not receive the SANITY response in the given time.
1. Wait for 5 minutes and see if board is visible to the system by using list
2. If the board is visible, run the test again. If same abort code results,
3. If the board is not visible to the system with the list configuration all
4. If the board is still not recognized by the system, replace the board.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error
1. Try to reset the board again.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS
The ATM-EI circuit pack is successfully reset.
1. If the status port-network command still indicates that this link is down, it
2. If the links do not come up after reset, review the error logs and take
8-224
Issue 1 May 2002
command.
config all command.
escalate the problem.
command, reseat the board.
is possible that one or both of the ATM-EI circuit packs are busied out.
appropriate diagnostic action.
Continued on next page