Maintenance-Object Repair Procedures
Critical Reliability
1. Enter status pnc, and ensure that the A-PNC is active.
If not, request a PNC interchange using the reset pnc interchange
command.
2. Enter busyout pnc-standby.
3. Enter change system-parameters duplication, and change the Enable
Operation of PNC Duplication field to n.
4. Enter busyout atm pnc n (port network's number).
5. Enter remove atm pnc n (port network's number) to remove both ATM-EI
boards, or enter change atm pnc to remove the B-side ATM-EI board.
6. Enter change system-parameters duplication, and change the Enable
Operation of PNC Duplication field to y.
Changing Circuit Pack Location or ATM Address
Standard, Duplex or High Reliability
NOTE:
These systems are not equipped with PNC duplication.
1. Remove the ATM PNC connection (see
Connections''
2. Add an ATM PNC connection (see
above).
A-side ATM-EI—Critical Reliability
1. Remove the ATM PNC connection (see
Connections''
2. Add an ATM PNC connection (see
above).
B-side ATM-EI—Critical Reliability
1. Enter status pnc, and ensure that the A-PNC is active.
If not, request a pnc interchange using the reset pnc interchange
command.
2. Enter busyout pnc-standby.
3. Enter list config carrier, and verify that an ATM circuit pack is assigned for
the new location. If not, add the ATM circuit pack's translations.
4. Enter busyout atm pnc n (connection number) b-pnc.
5. Enter change atm pnc n (connection number) and change circuit pack
location for the B side.
6. Enter release pnc-standby.