Test Alarms - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands

test alarms

This command tests the hardware associated with selected alarms
Synopsis
test alarms [auto-page] [failures] [step] [short | long] [repeat-number | clear]
Permissions
The following default logins may execute this command: system technician,
inads, init, nms.
Examples
test alarms
test alarms step failures
test alarms long clear auto-page
test alarms long failures
Description
This command allows the technician to automatically test all of the hardware that
is associated with the active alarms in the alarm log. This command provides a
query form to help the user narrow the selection of alarmed objects. Once the
form is filled out, the user presses
selected alarm log entries is tested. The results will be displayed in standard test
output and status information will be displayed on the message line as the
command progresses.
Several alarms may be logged against a single maintenance object, each alarm
representing a different problem. Even if there are multiple entries in the alarm
log for a single object, the test alarms command will only test each physical object
once.
Defaults
The default options for this command are: short, repeat of 1.
7-410
Issue 1 May 2002
and the hardware associated with the
ENTER