ADX16D-P (16-Port AUDIX Digital Port)
Error Log Entries and Test to Clear Values
Table 8-9. EMBEDDED AUDIX Digital Port Error Log Entries
Error
Aux
Type
Data
1
0
0
1(a)
40987
1(b)
1 to 20
15(c)
Any
18(d)
0
23(e)
0
130(f)
257(g)
40971
513(h)
Any
1537(i)
40968
1793
2049
2305(j)
40967
3840(k)
40965
3840(l)
41029
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms may be downgraded to Warning alarms based on the values used in the set options command.
Notes:
a. The user may experience a noisy port or link, due to an off-board problem
that is detected by the port circuit. If so, replace the circuit pack (see
caution at the beginning of this section). Once the problem is resolved, the
alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is
incremented. Also see Note a, above.
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. Release the port with the release
port UUCSSpp command.
555-233-143
Associated
Alarm
Test
Level
Any
Any
None
WARNING
None
WARNING
None
busyout port
WARNING
UUCSSpp
None
WARNING
None
WARNING
None
None
None
WARNING
Voice and
MINOR
Control Local
WARNING
Loop Test
(#13)
NPE Crosstalk
MINOR
test (#9)
WARNING
None
None
None
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
OFF
OFF
OFF
release port UUCSSpp
OFF
ON
test port UUCSSpp sh
OFF
ON
test port UUCSSpp l r 3
2
ON
test port UUCSSpp l r 3
2