AN-LN-PT (Analog Line Port)
Table 8-40. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
2. Use the status station extension command to determine the service
3. If the port is active, wait until it is idle before testing. Retry the command at
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1018
ABORT
Administration has disabled the test. The default for the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test #48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
2. Change the
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run test are not available. This could be due to a
failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
This test can fail due to either on- or off-board problems. Off-board problems
include TDM-BUS faults, EXP-PN and EXP-INTF faults, and faults associated
with the Tone Detectors/Tone Generators. Clear every off-board problem
before replacing the board.
1. A TDM-BUS problem is usually the result of a faulty board connection to
2. Resolve any EXP-PN and EXP-INTF errors in the error log.
3. Resolve any TONE-BD and/or TONE-PT errors in the error log.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. Replace
PASS
The port is correctly using its allocated time slots. Investigate user-reported
troubles on this port by running other port tests, by examining station wiring, or
by inspecting the station.
555-233-143
extension.
state of the port.
1-minute intervals up to 5 times.
station extension.
Test?
field on the station form to y.
the backplane, or bent pins on the backplane. Resolve any TDM-BUS
errors in the error log.
the board only if the test fails.
field on the
Test?
Continued on next page