Maintenance-Object Repair Procedures
Table 8-91. ATM Board Framer Loop-Around Test (#1260) — Continued
Error
Test
Code
Result
Description / Recommendation
6
FAIL
A previously-established loop around was not released.
1. Issue the reset board UUCSS command.
2. Retry the command at 1-minute intervals up to 3 times.
3. If this test continues to fail, replace the ATM-EI circuit pack.
4. Test the new ATM-EI circuit pack (test board UUCSS long).
PASS
The ATM-EI board is functioning properly, however this test does not verify that
the optical portion of the lightwave transceiver is functioning.
0
NO
No board was detected by the test.
BOARD
1. Resolve either wrong board (Error 125) or no board (Error 131) issues, if
2. Check that the board is properly translated and inserted. If so, check for
3. Run the test again. If it fails, the NCE chip on board could be bad.
8-222
Issue 1 May 2002
applicable.
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
Replace the board and retest.