Avaya S8700 Maintenance Manual page 901

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ATM-BCH (ATM B-Channel Trunk)
ISDN Test Call Test (#258)
This nondestructive test performs a far-end loop-around test over an ATM-BCH
trunk if:
The trunk is IN-SERVICE, MAINTENANCE/NEAR-END, or
OUT-OF-SERVICE/NEAR-END.
No calls are active on the trunk.
The system uses country protocol 1 (including US), or the far end has
loop-around capability.
The test sets up a call to a far-end switch over the ATM-BCH trunk. Then the
digital port on a TN711D Maintenance/Test circuit pack sends a bit pattern to the
far end and back. If the received pattern matches that sent, the test passes. If
there are differences, it fails.
Synchronous Test Calls
You can initiate a synchronous outgoing test call (including a test call for
ISDN-PRI trunks) with these commands:
test trunk grp#/mbr# long [repeat#]
test board UUCSS long [repeat#]
test port UUCSSpp long [repeat#]
Table 8-74. Test #258 ISDN Test Call
Error
Test
Code
Result
Description / Recommendation
4
ABORT
Signaling channel problem
1. Look for errors or alarms against the
8
ABORT
TN230x circuit-pack problem
1. See the
1004
ABORT
B channel is active.
1. See if a call is active. Run status trunk grp#/mbr# command.
2. If the service state is In-Service/Idle, retry the test.
1005
ABORT
Bad configuration (for example, no Maintenance/Test circuit pack)
1. Make sure that the Maintenance/Test circuit pack is inserted.
2. Repeat the test.
1018
ABORT
Test call disabled
1. Enable Maintenance on the Trunk Group form.
555-233-143
and
''ATM-DCH (ATM D-Channel Port)''
''ATM-INTF (TN2305/6)''
''ATM-SGRP (ATM Signaling Group)''
MOs.
MO.
Continued on next page