Avaya S8700 Maintenance Manual page 230

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Additional Maintenance Procedures
Output Fields—ATMS Detail Report
Measurements are made in both directions, near to far end, and far to near end.
For each measurement, there are two columns on the lower part of the report,
"NE" for near end, and "FE" for far end. These refer to the destination end for that
measurement.
The trunk-group number selected
Group
The trunk-group type
Type
The vendor of this trunk group
Vendor
The type of terminating test line on the switch at the far end of the trunk to which
TTL Type
the test call was made
The list of marginal and unacceptable threshold values for each type of
Threshold
measurement as defined on the Trunk Group form
Values
The trunk-group member number
Trk Mem
The month and day this trunk was last tested
Test Date
The time of day this trunk was last tested
Test Time
The results of the trunk transmission test as follows:
Tst Rslt
pass
The test call completed successfully and trunk performance was satisfactory.
marg
Trunk measurements exceeded the marginal threshold, but not the unacceptable.
fail
Trunk measurements exceeded the unacceptable threshold.
xxxx
A numerical error code indicates the reason for an aborted test call. The codes
are explained in the CO-TRK and TIE-TRK sections of
ISDN-BRI Port)'' on page
blank
A blank line indicates that no measurements have been made on this trunk since
the database was last initialized.
Far-to-near and near-to-far measurements of 1004-Hz loss from low-level tone.
1004Hz-loss
Min
Far-to-near and near-to-far measurements of 1004-Hz loss at 0 dBm.
1004Hz-loss
Max
These low-frequency transmission tests measure maximum positive and negative
Loss dev at
deviation of +9 and -9 dB from the 1004-Hz loss measurements.
404Hz
These high-frequency transmission tests measure maximum positive and
Loss dev at
negative deviation of +9 and -9 dB from the 1004-Hz loss measurements.
2804Hz
Maximum interference noise on a voice terminal within the voice-band frequency
C-msg Noise
range (500 to 2500 Hz). The measurement ranges from 15 to 55 dBrnC (decibels
above reference noise).
Maximum signal-dependent noise interference on a line between 34 and 74
C-ntch Noise
dBrnC.
5-44
Issue 1 May 2002
8-3.