Avaya S8700 Maintenance Manual page 953

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ATM-INTF (TN2305/6)
Control Channel Loop-Around Test
This test queries the circuit pack for its circuit-pack code and vintage and verifies
its records.
Table 8-98. Test #52: Control Channel Loop-Around
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
The response to the test request was not received within the allowable time
period.
2100
ABORT
The system resources required to this test are not available.
2500
ABORT
Internal system error — Retry the command at 1-minute intervals up to 5 times.
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues, reset the circuit pack.
3. Retry the command up to 5 times.
PASS
Communication with this circuit pack is successful.
Any
NO
This is normal if the test is being executed when:
BOARD
1. The board is not physically in the system.
2. The system is booting.
Otherwise, there is some inconsistency in the date stored in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in the process of booting.
3. Retry the command at 1-minute intervals up to 5 times.
555-233-143
Continued on next page
Issue 1 May 2002
8-231

Advertisement

Table of Contents
loading

Table of Contents